Home > News

JS Series Concrete Mixer Common Failure

2013-03-14 09:51:54

JS series twin-shaft forced concrete mixer common fault: Fault phenomenon: mixing blade support arm loose liner causes: connecting bolts loose, lining arrhythmia solution: tightening the connecting bolts, leveling linerstirring motor; fault phenomenon: stop operation causes: overload, stirring barrel large stones stuck mixing blades; rated current of the thermal relay tone small solution to: Exclude concrete blender blade and liner cardliving stones, start the thermal relay is reset. Adjust the thermal relay setting current value, so that it is equal to or slightly larger than the motor 1H.
The twin-shaft forced concrete mixer JS series is a very special concrete mixing machine JS Series twin-shaft forced concrete mixer is a project with a concrete mixer, commonly used in HZS series concrete mixing station with PLD series concrete batching machine use, the normal operation of the JS series twin-shaft forced concrete mixer, related to the common use of the entire HZS series concrete mixing station. So be sure to understand the common fault of the twin-shaft forced concrete mixer JS series.

 

 

Related Products:

 

JS4000 Concrete Mixer.jpgJS4000 Concrete Mixer

Model: JS4000
Discharge volume: 4000L
Charging volume: 6400L
Theoretical capacity: ≥200m3

 

 

JS3500 Concrete Mixer.jpgJS3500 Concrete Mixer

Model: JS3500
Discharge volume: 3500L
Charging volume: 5600L
Theoretical capacity: ≥180m3